Mettler electronic balance method

<

How should METTLER electronic balances be used, and what are the precautions when using them? The following will be explained in detail by Shanghai Bayu technical staff:

First, the use of METTLER electronic balance

1 , the balance starts
After the electronic balance is energized, it should be kept energized. Do not unplug the power after turning off the electronic balance. If the power is removed, the internal temperature of the electronic balance will be out of balance. Because the electronic components are always energized, we will use the electronic scale next time. When the amount is used, it needs to be preheated. When using the electronic balance for the first time, we need to preheat the electronic balance. According to the model of the electronic balance, the warm-up time is also different. The length of the warm-up time should be determined according to the manual. .
2 , adjustment level
We use the leveling feet of the electronic balance to adjust the level, check the level indicator, only the bubble is in the center of the horizontal to indicate that the electronic balance is placed in a horizontal position, we must correct the electronic balance after each adjustment level.
3 , correction
Only when the balance is calibrated regularly, the indication error of the electronic balance can be reduced as much as possible. In the following cases, we must correct the electronic balance in time : 1. When using the electronic balance for the first time; 2 , replace When the position of the electronic balance is placed; 3 , after adjusting the horizontal position of the electronic balance , 4 , the use environment of the electronic balance has undergone relatively large changes, such as changes in temperature and humidity environment.
In general, when we use METTLER electronic balances for weighing, we must pay attention to the above points. This operation not only makes our weighing results more accurate, but also makes us use our electronic balances. The service life.
Second, METTLER electronic balance use precautions
1. Unplug the power supply before cleaning.
2 , the weighing plate can not be pulled out at will, so as not to damage the sensor, to rotate left and right, take it out, it is best not to take it.
3. Do not use corrosive cleaning agents (such as items of volume). Use a soft, lint-free cloth dampened with water and then apply some neutral detergent (soap).
4. When cleaning, please be careful not to let water drip into the balance. After cleaning, use a clean, lint-free cloth to dry the balance carefully.
5. Avoid contact with strong magnetic objects.